Keeguard roof railing exceeds this requirement and has the testing documents to prove it.
Roof edge guardrail requirements.
The top edge height may exceed 45 inches 1 14 m provided the guardrail system meets all other criteria of paragraph b of this section.
1910 29 b 1 the top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
Required guards shall be not less than 42 inches 1 07m high measured vertically as follows.
The 1926 standard doesn t make specific mention to distance from roof edge but again states that for roofing work on low slope roofs with unprotected sides and edges 6 feet 1 8 m or more above lower levels shall be protected from falling by guardrail systems safety net systems personal fall arrest systems or a combination of those systems.
When conditions warrant the height of the top edge may exceed the 45 inch height provided the guardrail system meets all other criteria of this paragraph.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 of this section.
The top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
From the adjacent walking surfaces.
In addition the code continues to specifically address fall protection near mechanical equipment which is where the edge accufit safety railing was being placed to protect requirements stating guards shall be provided where various components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762mm above the floor roof or grade below.
Top edge height of top rails or equivalent guardrail system members shall be 42 inches 1 1 m plus or minus 3 inches 8 cm above the walking working level.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 below.
Between 6 feet and 15 feet from the edge.
6 feet from the edge.
For general industry working at a 4 foot height or a low sloped roof osha requires.
The guard shall extend not less than 30.
1910 29 b 3 osha requires that guardrail systems must be able to withstand a force of at least 200 lbs of point load without failure.
Guards shall be provided where appliance equipment fans roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches above floor roof or grade below.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
Industry standard says that protection must be in place for anyone working within 15 feet of the roof edge.
Osha 1910 29 b contains system requirements that employers must follow to ensure guardrail systems will protect workers from falling to lower levels.